10 pvc sch 80 120 f.
Sch 80 pvc pipe temperature rating.
Schedule 80 pvc technical information.
Maximum pvc service temperature 140 f.
Schedule 80 pvc pipe dimensions pressure ratings.
Check on line catalog www spearsmfg.
As the temperature of the pvc increases the pressure that the pvc can withstand will decrease.
The chart below will illustrate the pressure derating of pvc as temperatures increase.
Made in the u s a.
The specifi ed derating factors for cpvc are suitable for pipe conveying water at elevated temperatures.
120 f the maximum service temperature for pvc is 140 f.
The pressure ratings given above are for water non shock 73 f.
To calculate elevated temperature rating use the following formula.
Schedule 80 pvc pipe dimensions pressure ratings.
Schedule 80 pvc pipe dimensions pressure ratings.
230 psi x 0 40 92 psi max.
Due to material cost variations prices subject to change.
Made in the u s a suitable for oil free air handling to 25 psi not for distribution of compressed air or gaspage 336.
Maximum pvc service temperature 140 f.
Schedule 80 cpvc technical information schedule 80 cpvc pipe dimensions pressure ratings maximum cpvc service temperature 200 f pressure de rating at elevated temperatures the pressure ratings given above are for water non shock 73 f.
The speci fi ed derating factors for pvc are suitable for pipe conveying water at elevated temperatures.
Max pressure 73 x derating factor schedule 80 pipe.
Maximum pvc service temperature 140 f pressure de rating at elevated temperatures.
The pressure ratings above are for water at 73 degrees fahrenheit.
Multiply the working pressure rating of the selected pipe at 73 f by the appropriate de rating factor to determine the maximum working pressure rating of the pipe at the elevated temperature chosen.