Find pilot light assembly.
Snyder general furnace pilot light.
To relight the pilot follow the manufacturer s instructions exactly.
If your furnace is still malfunctioning after you ve repaired or replaced the thermocouple and determined the flow of gas isn t a problem you ll need the aid of an experienced.
Private videos 356 945 views.
Waukesha furnace repair pros help you diagnose and repair pilot light problems do it yourself maintenance and repairs can only go so far unfortunately.
Furnace pilot light fix replace 10 thermocouple.
A modern gas furnace usually has an electronic spark generator to ignite the gas when the thermostat calls for heat.
It s not clear to me if voltage needs to be present at the gas valve in order for the pilot to operate.
A number of things can make an old furnace pilot light go out including a strong draft a faulty thermocouple or a loss of gas.
I cant make out the input output btu.
Dw shows you how to light an old 1986 snyder general gas furnace without a turning nob in 2 minutes.
Snyder general gas furnace operation and troubleshoot when troubleshooting understand you are working with potentially lethal voltages and a highly flammable gas.
This system uses a pilot flame but the pilot lights only when there s a call for heat from the thermostat the furnace s electronic control board activates an electric igniter that uses a.
I have a snyder general furnace comfortmaker model gua060a012ain serial r883800159 manuf 9 88 the furnace engages and begins its cycle but just runs without lighting auto pilot.
They are usually fastened to the furnace.
Most of the time it causes the pilot light to go out.
There is a standing pilot light with a thermo couple both of which are connected to the gas valve.
The pilot is presently out.
If instructions for relighting the pilot are not provided follow this general procedure.
Intermittent pilot ignition.
One type of electronic ignition is an intermittent pilot.
An older gas furnace has a standing pilot that stays on all the time or at least it s supposed to.
If you have a newer furnace or one with an afue rating above 80 it most likely has an electronic ignition system.
If you do not have the ability to do these operations safely do not attempt them.
1988 snyder general furnace duration.
Kevin read more.
It typically has a gas valve with on off and.
Why wont this gas furnace light duration.
Thermostat is on hi and the house is cold.
I have a snyder general model gde00a012an furnace that flashes back about every 3 to 4 time the burners ignite.
How to turn your furnace pilot light on duration.
The pilot light on a gas furnace can go out because of drafts.